3X Start Page Add 3X to bookmark Print this page Site map   FR   SP   CHN  
 

The specialist in pipe repair: leaks, corrosion and other defects  

  Home   Products Services 3X engineering Distributors News Contact us FaQ  
3X distributors in the world
Download
 3X Flyer
 STOPKiT Flyer
 REINFORCEKiT-4D Flyer
 REINFORCEKiT-Evolution Flyer
 REFLANGEKiT-SF6 Flyer
 MBX© Bristle Blaster Flyer
 MBX© ATEX conformity
Our clients







REINFORCEKiT Evolution | REINFORCEKiT 4D | REINFORCEKiT Watersleeve | STOPKiT | REFLANGEKiT SF6 | REFLANGEKiT Oil
 
1°)STOPKiT preparation
- Joining STOPKiT

- Place the patch in the middle of the strap
Material: 
- Torque ratchet 6 to 8 parts 
- Recycling bin  

Control: 
- Fat on the screws, washers 
- Diameter of the tube 
- Orientation head screws
 
2°) Preparing the pipe
- Place the two witnesses 
at both ends of the repair
Material: 
- 2 metal Témoins 3X 
- Formwork 

Control: 
- Position of witnesses
 
3°) Assembly on the pipe
- Place the patch in the vicinity of the leak 

- Tighten allowing freedom of movement
Material: 
- Torque ratchet 6 to 8 parts 

Control: 
- Center the patch on the strap
 
4°) Stopping the leak
- Drag the markers to STOPKiT 

- Screw alternately 

- Keep the patch centered
Material: 
- Protection PPE 
- Key ratchet 8 

Control: 
- Centering the patch on the leak on the strap
 
5°) Optimal clamping
- Tighten to 40N / m 

- Tighten the nuts anti vibration 

- Check the tightening 40N / m after 8 am
Material: 
- Torque wrench 
- Wrench 17 

Control: 
- No Leakage 
- Complete tracking sheet
 
6°) STOPKiT PERMANENT installation
- Install the shell 

- Fill with resin 3X
Material: 
- 3X kit special

Control: 
- Refer to specific procedure
 
 
3X Engineering : 9, avenue Albert II - 98 000 MONACO - Tel : + 377 92 05 79 81 - Fax : + 377 92 05 72 71 - E-mail : 3x@3xeng.com